{"product_id":"jarsh-atex-certified-industrial-blower-fan-with-anti-static-pvc-duct","title":"Jarsh ATEX Certified Industrial Blower Fan with Anti-Static PVC Ventilation Duct | Explosion Proof Hazardous Area Ventilation System","description":"\u003ch2 data-end=\"306\" data-start=\"223\" data-section-id=\"1lvxtww\"\u003eJarsh ATEX Certified Industrial Blower Fan with Anti-Static PVC Ventilation Duct\u003c\/h2\u003e\n\u003cp data-end=\"820\" data-start=\"308\"\u003eThe \u003cstrong data-end=\"396\" data-start=\"312\"\u003eJarsh ATEX Certified Industrial Blower Fan with Anti-Static PVC Ventilation Duct\u003c\/strong\u003e is a heavy-duty explosion-proof ventilation solution designed for hazardous environments where safe airflow management is critical. Engineered for use in oil \u0026amp; gas facilities, chemical plants, confined spaces, refineries, marine operations, industrial maintenance projects, and explosive atmosphere zones, this industrial ventilation system delivers powerful airflow while complying with stringent ATEX safety requirements.\u003c\/p\u003e\n\u003cp data-end=\"1202\" data-start=\"822\"\u003eBuilt with a durable carbon steel housing, corrosion-resistant powder-coated finish, and integrated anti-static ducting, the blower ensures safe and efficient ventilation, fume extraction, fresh air supply, and confined space air circulation. The retractable anti-static duct allows easy deployment in challenging industrial environments while minimizing static electricity risks.\u003c\/p\u003e\n\u003cp data-end=\"1406\" data-start=\"1204\"\u003eDesigned for reliability and portability, the blower features a rugged carrying handle, vibration-reducing rubber feet, high-performance motor, and optimized fan housing for superior airflow efficiency.\u003c\/p\u003e\n\u003chr data-end=\"1411\" data-start=\"1408\"\u003e\n\u003ch2 data-end=\"1428\" data-start=\"1413\" data-section-id=\"1ma7m6t\"\u003eKey Features\u003c\/h2\u003e\n\u003cp data-end=\"1473\" data-start=\"1430\"\u003e✔ ATEX Certified Explosion-Proof Blower Fan\u003c\/p\u003e\n\u003cp data-end=\"1523\" data-start=\"1475\"\u003e✔ Suitable for Hazardous \u0026amp; Explosive Atmospheres\u003c\/p\u003e\n\u003cp data-end=\"1568\" data-start=\"1525\"\u003e✔ Anti-Static PVC Ventilation Duct Included\u003c\/p\u003e\n\u003cp data-end=\"1614\" data-start=\"1570\"\u003e✔ High Airflow Industrial Ventilation System\u003c\/p\u003e\n\u003cp data-end=\"1654\" data-start=\"1616\"\u003e✔ Heavy-Duty Carbon Steel Construction\u003c\/p\u003e\n\u003cp data-end=\"1698\" data-start=\"1656\"\u003e✔ Corrosion Resistant Powder-Coated Finish\u003c\/p\u003e\n\u003cp data-end=\"1738\" data-start=\"1700\"\u003e✔ Portable Design with Carrying Handle\u003c\/p\u003e\n\u003cp data-end=\"1768\" data-start=\"1740\"\u003e✔ Rubber Anti-Vibration Feet\u003c\/p\u003e\n\u003cp data-end=\"1807\" data-start=\"1770\"\u003e✔ Confined Space Ventilation Solution\u003c\/p\u003e\n\u003cp data-end=\"1844\" data-start=\"1809\"\u003e✔ Industrial Fume Extraction System\u003c\/p\u003e\n\u003cp data-end=\"1895\" data-start=\"1846\"\u003e✔ Fresh Air Supply \u0026amp; Air Circulation Applications\u003c\/p\u003e\n\u003cp data-end=\"1938\" data-start=\"1897\"\u003e✔ OSHA-Compliant Industrial Safety Design\u003c\/p\u003e\n\u003cp data-end=\"1979\" data-start=\"1940\"\u003e✔ Durable Industrial Grade Construction\u003c\/p\u003e\n\u003cp data-end=\"2027\" data-start=\"1981\"\u003e✔ Multiple Sizes Available from 200mm to 600mm\u003c\/p\u003e\n\u003chr data-end=\"2032\" data-start=\"2029\"\u003e\n\u003ch2 data-end=\"2053\" data-start=\"2034\" data-section-id=\"1p927wt\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp data-end=\"2334\" data-start=\"2055\"\u003eThe Jarsh ATEX Blower Fan is specially designed for ventilation in hazardous environments where combustible gases, vapors, dust, or explosive atmospheres may be present. The blower provides reliable air movement for worker safety, environmental control, and equipment protection.\u003c\/p\u003e\n\u003cp data-end=\"2518\" data-start=\"2336\"\u003eThe integrated anti-static ventilation duct safely channels airflow into confined spaces, tanks, vessels, tunnels, pits, and industrial work zones while reducing static accumulation.\u003c\/p\u003e\n\u003chr data-end=\"2523\" data-start=\"2520\"\u003e\n\u003ch2 data-end=\"2552\" data-start=\"2525\" data-section-id=\"1exquw6\"\u003eConstruction \u0026amp; Materials\u003c\/h2\u003e\n\u003ch3 data-end=\"2565\" data-start=\"2554\" data-section-id=\"ct20g7\"\u003eHousing\u003c\/h3\u003e\n\u003cul data-end=\"2611\" data-start=\"2566\"\u003e\n\u003cli data-end=\"2611\" data-start=\"2566\" data-section-id=\"mcsfyo\"\u003eHeavy-Duty 16-Gauge Carbon Reinforced Steel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"2623\" data-start=\"2613\" data-section-id=\"cu8xzp\"\u003eFinish\u003c\/h3\u003e\n\u003cul data-end=\"2698\" data-start=\"2624\"\u003e\n\u003cli data-end=\"2657\" data-start=\"2624\" data-section-id=\"1w3xsm\"\u003eIndustrial Epoxy Powder Coating\u003c\/li\u003e\n\u003cli data-end=\"2698\" data-start=\"2658\" data-section-id=\"1usg12v\"\u003eCorrosion Resistant Surface Protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"2709\" data-start=\"2700\" data-section-id=\"6tyo7u\"\u003eGrill\u003c\/h3\u003e\n\u003cul data-end=\"2744\" data-start=\"2710\"\u003e\n\u003cli data-end=\"2744\" data-start=\"2710\" data-section-id=\"1shu682\"\u003eSilver Metal-Coated Safety Guard\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"2763\" data-start=\"2746\" data-section-id=\"1dk00uj\"\u003eDuct Material\u003c\/h3\u003e\n\u003cul data-end=\"2910\" data-start=\"2764\"\u003e\n\u003cli data-end=\"2802\" data-start=\"2764\" data-section-id=\"6w9ixp\"\u003eConstruction Grade Vinyl \u0026amp; Polyester\u003c\/li\u003e\n\u003cli data-end=\"2836\" data-start=\"2803\" data-section-id=\"13cqa46\"\u003eAnti-Static Single-Ply Material\u003c\/li\u003e\n\u003cli data-end=\"2879\" data-start=\"2837\" data-section-id=\"rbwbyl\"\u003eNeoprene Coating for Enhanced Durability\u003c\/li\u003e\n\u003cli data-end=\"2910\" data-start=\"2880\" data-section-id=\"mya8d5\"\u003eFlame Retardant Construction\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"2915\" data-start=\"2912\"\u003e\n\u003ch2 data-end=\"2940\" data-start=\"2917\" data-section-id=\"idtnn7\"\u003eVentilation Features\u003c\/h2\u003e\n\u003cul data-end=\"3200\" data-start=\"2942\"\u003e\n\u003cli data-end=\"2968\" data-start=\"2942\" data-section-id=\"xc1w20\"\u003eFlanged Duct Connections\u003c\/li\u003e\n\u003cli data-end=\"3006\" data-start=\"2969\" data-section-id=\"g6771o\"\u003eIntake \u0026amp; Exhaust Airflow Capability\u003c\/li\u003e\n\u003cli data-end=\"3046\" data-start=\"3007\" data-section-id=\"1ve8jdz\"\u003eFlexible Retractable Ventilation Duct\u003c\/li\u003e\n\u003cli data-end=\"3080\" data-start=\"3047\" data-section-id=\"zgmr5n\"\u003eAnti-Static Air Transfer System\u003c\/li\u003e\n\u003cli data-end=\"3117\" data-start=\"3081\" data-section-id=\"1v3ca1c\"\u003eConfined Space Ventilation Support\u003c\/li\u003e\n\u003cli data-end=\"3159\" data-start=\"3118\" data-section-id=\"1kjrn7c\"\u003eIndustrial Fume Extraction Applications\u003c\/li\u003e\n\u003cli data-end=\"3200\" data-start=\"3160\" data-section-id=\"rbn37s\"\u003ePositive \u0026amp; Negative Airflow Operations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"3205\" data-start=\"3202\"\u003e\n\u003ch2 data-end=\"3235\" data-start=\"3207\" data-section-id=\"xggplx\"\u003eElectrical Specifications\u003c\/h2\u003e\n\u003cul data-end=\"3337\" data-start=\"3237\"\u003e\n\u003cli data-end=\"3259\" data-start=\"3237\" data-section-id=\"8kfo1l\"\u003eVoltage: 220V \/ 240V\u003c\/li\u003e\n\u003cli data-end=\"3284\" data-start=\"3260\" data-section-id=\"p1tmxm\"\u003eFrequency: 50Hz \/ 60Hz\u003c\/li\u003e\n\u003cli data-end=\"3309\" data-start=\"3285\" data-section-id=\"1xkr65t\"\u003eIndustrial Grade Motor\u003c\/li\u003e\n\u003cli data-end=\"3337\" data-start=\"3310\" data-section-id=\"g0s17w\"\u003eContinuous Duty Operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"3342\" data-start=\"3339\"\u003e\n\u003ch2 data-end=\"3390\" data-start=\"3344\" data-section-id=\"18659ej\"\u003eAvailable Models \u0026amp; Technical Specifications\u003c\/h2\u003e\n\u003ch3 data-end=\"3413\" data-start=\"3392\" data-section-id=\"1nqm8xy\"\u003eJIB-ATEX-200 (8\")\u003c\/h3\u003e\n\u003cul data-end=\"3534\" data-start=\"3414\"\u003e\n\u003cli data-end=\"3427\" data-start=\"3414\" data-section-id=\"hpt0nf\"\u003ePower: 230W\u003c\/li\u003e\n\u003cli data-end=\"3452\" data-start=\"3428\" data-section-id=\"1pg8ebj\"\u003eSpeed: 2800 \/ 3300 RPM\u003c\/li\u003e\n\u003cli data-end=\"3487\" data-start=\"3453\" data-section-id=\"o45wu3\"\u003eAirflow Capacity: 25 \/ 35 m³\/min\u003c\/li\u003e\n\u003cli data-end=\"3513\" data-start=\"3488\" data-section-id=\"1l9kmgd\"\u003eStatic Pressure: 245 Pa\u003c\/li\u003e\n\u003cli data-end=\"3534\" data-start=\"3514\" data-section-id=\"i3zqvu\"\u003eNoise Level: 60 dB\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"3558\" data-start=\"3536\" data-section-id=\"sj7dne\"\u003eJIB-ATEX-250 (10\")\u003c\/h3\u003e\n\u003cul data-end=\"3679\" data-start=\"3559\"\u003e\n\u003cli data-end=\"3572\" data-start=\"3559\" data-section-id=\"hpqtpn\"\u003ePower: 320W\u003c\/li\u003e\n\u003cli data-end=\"3597\" data-start=\"3573\" data-section-id=\"1pg8ebj\"\u003eSpeed: 2800 \/ 3300 RPM\u003c\/li\u003e\n\u003cli data-end=\"3632\" data-start=\"3598\" data-section-id=\"zqh6nv\"\u003eAirflow Capacity: 43 \/ 53 m³\/min\u003c\/li\u003e\n\u003cli data-end=\"3658\" data-start=\"3633\" data-section-id=\"1l4k8xt\"\u003eStatic Pressure: 294 Pa\u003c\/li\u003e\n\u003cli data-end=\"3679\" data-start=\"3659\" data-section-id=\"i3tl1u\"\u003eNoise Level: 68 dB\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"3703\" data-start=\"3681\" data-section-id=\"1v9ony4\"\u003eJIB-ATEX-300 (12\")\u003c\/h3\u003e\n\u003cul data-end=\"3824\" data-start=\"3704\"\u003e\n\u003cli data-end=\"3717\" data-start=\"3704\" data-section-id=\"hpmalp\"\u003ePower: 520W\u003c\/li\u003e\n\u003cli data-end=\"3742\" data-start=\"3718\" data-section-id=\"1pg8ebj\"\u003eSpeed: 2800 \/ 3300 RPM\u003c\/li\u003e\n\u003cli data-end=\"3777\" data-start=\"3743\" data-section-id=\"17ugf0b\"\u003eAirflow Capacity: 65 \/ 75 m³\/min\u003c\/li\u003e\n\u003cli data-end=\"3803\" data-start=\"3778\" data-section-id=\"1jdqs3t\"\u003eStatic Pressure: 373 Pa\u003c\/li\u003e\n\u003cli data-end=\"3824\" data-start=\"3804\" data-section-id=\"i60bwa\"\u003eNoise Level: 71 dB\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"3848\" data-start=\"3826\" data-section-id=\"va6l0f\"\u003eJIB-ATEX-350 (14\")\u003c\/h3\u003e\n\u003cul data-end=\"3969\" data-start=\"3849\"\u003e\n\u003cli data-end=\"3862\" data-start=\"3849\" data-section-id=\"hpnv1k\"\u003ePower: 750W\u003c\/li\u003e\n\u003cli data-end=\"3887\" data-start=\"3863\" data-section-id=\"1pg8ebj\"\u003eSpeed: 2800 \/ 3300 RPM\u003c\/li\u003e\n\u003cli data-end=\"3922\" data-start=\"3888\" data-section-id=\"1dqohi1\"\u003eAirflow Capacity: 82 \/ 90 m³\/min\u003c\/li\u003e\n\u003cli data-end=\"3948\" data-start=\"3923\" data-section-id=\"1hz3q22\"\u003eStatic Pressure: 598 Pa\u003c\/li\u003e\n\u003cli data-end=\"3969\" data-start=\"3949\" data-section-id=\"i61259\"\u003eNoise Level: 76 dB\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"3993\" data-start=\"3971\" data-section-id=\"1ny8bgf\"\u003eJIB-ATEX-400 (16\")\u003c\/h3\u003e\n\u003cul data-end=\"4110\" data-start=\"3994\"\u003e\n\u003cli data-end=\"4008\" data-start=\"3994\" data-section-id=\"gbapiy\"\u003ePower: 1100W\u003c\/li\u003e\n\u003cli data-end=\"4033\" data-start=\"4009\" data-section-id=\"1pg8ebj\"\u003eSpeed: 2800 \/ 3300 RPM\u003c\/li\u003e\n\u003cli data-end=\"4063\" data-start=\"4034\" data-section-id=\"1r8igqi\"\u003eAirflow Capacity: 96 m³\/min\u003c\/li\u003e\n\u003cli data-end=\"4089\" data-start=\"4064\" data-section-id=\"1gun67d\"\u003eStatic Pressure: 700 Pa\u003c\/li\u003e\n\u003cli data-end=\"4110\" data-start=\"4090\" data-section-id=\"hwxnpw\"\u003eNoise Level: 80 dB\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"4134\" data-start=\"4112\" data-section-id=\"1q4p0es\"\u003eJIB-ATEX-450 (18\")\u003c\/h3\u003e\n\u003cul data-end=\"4244\" data-start=\"4135\"\u003e\n\u003cli data-end=\"4148\" data-start=\"4135\" data-section-id=\"hpnv1k\"\u003ePower: 750W\u003c\/li\u003e\n\u003cli data-end=\"4166\" data-start=\"4149\" data-section-id=\"1m944vu\"\u003eSpeed: 1450 RPM\u003c\/li\u003e\n\u003cli data-end=\"4197\" data-start=\"4167\" data-section-id=\"18yjz1e\"\u003eAirflow Capacity: 160 m³\/min\u003c\/li\u003e\n\u003cli data-end=\"4223\" data-start=\"4198\" data-section-id=\"1ldp56y\"\u003eStatic Pressure: 224 Pa\u003c\/li\u003e\n\u003cli data-end=\"4244\" data-start=\"4224\" data-section-id=\"i5wfo3\"\u003eNoise Level: 78 dB\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"4268\" data-start=\"4246\" data-section-id=\"2mhf2z\"\u003eJIB-ATEX-500 (20\")\u003c\/h3\u003e\n\u003cul data-end=\"4379\" data-start=\"4269\"\u003e\n\u003cli data-end=\"4283\" data-start=\"4269\" data-section-id=\"gbapiy\"\u003ePower: 1100W\u003c\/li\u003e\n\u003cli data-end=\"4301\" data-start=\"4284\" data-section-id=\"1m944vu\"\u003eSpeed: 1450 RPM\u003c\/li\u003e\n\u003cli data-end=\"4332\" data-start=\"4302\" data-section-id=\"bv6jtw\"\u003eAirflow Capacity: 166 m³\/min\u003c\/li\u003e\n\u003cli data-end=\"4358\" data-start=\"4333\" data-section-id=\"1l8vxhn\"\u003eStatic Pressure: 270 Pa\u003c\/li\u003e\n\u003cli data-end=\"4379\" data-start=\"4359\" data-section-id=\"hx0qfk\"\u003eNoise Level: 84 dB\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"4403\" data-start=\"4381\" data-section-id=\"1uc9u3g\"\u003eJIB-ATEX-600 (24\")\u003c\/h3\u003e\n\u003cul data-end=\"4514\" data-start=\"4404\"\u003e\n\u003cli data-end=\"4418\" data-start=\"4404\" data-section-id=\"gerhp6\"\u003ePower: 2200W\u003c\/li\u003e\n\u003cli data-end=\"4436\" data-start=\"4419\" data-section-id=\"1m944vu\"\u003eSpeed: 1450 RPM\u003c\/li\u003e\n\u003cli data-end=\"4467\" data-start=\"4437\" data-section-id=\"j4lh5a\"\u003eAirflow Capacity: 290 m³\/min\u003c\/li\u003e\n\u003cli data-end=\"4493\" data-start=\"4468\" data-section-id=\"1jfuegd\"\u003eStatic Pressure: 300 Pa\u003c\/li\u003e\n\u003cli data-end=\"4514\" data-start=\"4494\" data-section-id=\"hz0bth\"\u003eNoise Level: 90 dB\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"4519\" data-start=\"4516\"\u003e\n\u003ch2 data-end=\"4536\" data-start=\"4521\" data-section-id=\"mu966k\"\u003eApplications\u003c\/h2\u003e\n\u003cul data-end=\"4976\" data-start=\"4538\"\u003e\n\u003cli data-end=\"4566\" data-start=\"4538\" data-section-id=\"1vfvjib\"\u003eHazardous Area Ventilation\u003c\/li\u003e\n\u003cli data-end=\"4590\" data-start=\"4567\" data-section-id=\"1il1nkf\"\u003eATEX Zone Ventilation\u003c\/li\u003e\n\u003cli data-end=\"4613\" data-start=\"4591\" data-section-id=\"t5wk36\"\u003eOil \u0026amp; Gas Facilities\u003c\/li\u003e\n\u003cli data-end=\"4636\" data-start=\"4614\" data-section-id=\"19rxq04\"\u003ePetrochemical Plants\u003c\/li\u003e\n\u003cli data-end=\"4661\" data-start=\"4637\" data-section-id=\"1ohn0ng\"\u003eChemical Manufacturing\u003c\/li\u003e\n\u003cli data-end=\"4682\" data-start=\"4662\" data-section-id=\"19qjseg\"\u003eOffshore Platforms\u003c\/li\u003e\n\u003cli data-end=\"4709\" data-start=\"4683\" data-section-id=\"tbd3ej\"\u003eTank Cleaning Operations\u003c\/li\u003e\n\u003cli data-end=\"4732\" data-start=\"4710\" data-section-id=\"kaxwpm\"\u003eConfined Space Entry\u003c\/li\u003e\n\u003cli data-end=\"4757\" data-start=\"4733\" data-section-id=\"1vaeb2q\"\u003eIndustrial Maintenance\u003c\/li\u003e\n\u003cli data-end=\"4777\" data-start=\"4758\" data-section-id=\"1ci7zj8\"\u003eMining Operations\u003c\/li\u003e\n\u003cli data-end=\"4809\" data-start=\"4778\" data-section-id=\"konz73\"\u003eMarine \u0026amp; Shipyard Ventilation\u003c\/li\u003e\n\u003cli data-end=\"4822\" data-start=\"4810\" data-section-id=\"2fb20m\"\u003eRefineries\u003c\/li\u003e\n\u003cli data-end=\"4840\" data-start=\"4823\" data-section-id=\"1d7jaur\"\u003eUtility Tunnels\u003c\/li\u003e\n\u003cli data-end=\"4860\" data-start=\"4841\" data-section-id=\"6mn4eb\"\u003eSewer Maintenance\u003c\/li\u003e\n\u003cli data-end=\"4889\" data-start=\"4861\" data-section-id=\"icpqtt\"\u003eIndustrial Fume Extraction\u003c\/li\u003e\n\u003cli data-end=\"4921\" data-start=\"4890\" data-section-id=\"jhwz2c\"\u003eEmergency Response Operations\u003c\/li\u003e\n\u003cli data-end=\"4953\" data-start=\"4922\" data-section-id=\"8eba4v\"\u003eConstruction Site Ventilation\u003c\/li\u003e\n\u003cli data-end=\"4976\" data-start=\"4954\" data-section-id=\"3k1tb9\"\u003eDust \u0026amp; Vapor Control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"4981\" data-start=\"4978\"\u003e\n\u003ch2 data-end=\"4994\" data-start=\"4983\" data-section-id=\"2qq1z5\"\u003eBenefits\u003c\/h2\u003e\n\u003cul data-end=\"5338\" data-start=\"4996\"\u003e\n\u003cli data-end=\"5032\" data-start=\"4996\" data-section-id=\"r2zwm6\"\u003eReduces hazardous gas accumulation\u003c\/li\u003e\n\u003cli data-end=\"5076\" data-start=\"5033\" data-section-id=\"duxhdl\"\u003eImproves worker safety in confined spaces\u003c\/li\u003e\n\u003cli data-end=\"5131\" data-start=\"5077\" data-section-id=\"1yny2vs\"\u003eSupports compliance with industrial safety standards\u003c\/li\u003e\n\u003cli data-end=\"5173\" data-start=\"5132\" data-section-id=\"n3kb6n\"\u003eProvides reliable fresh air circulation\u003c\/li\u003e\n\u003cli data-end=\"5203\" data-start=\"5174\" data-section-id=\"1csd9ji\"\u003ePortable and easy to deploy\u003c\/li\u003e\n\u003cli data-end=\"5250\" data-start=\"5204\" data-section-id=\"8adh9\"\u003eSuitable for continuous industrial operation\u003c\/li\u003e\n\u003cli data-end=\"5289\" data-start=\"5251\" data-section-id=\"zzqzt7\"\u003eMinimizes static electricity hazards\u003c\/li\u003e\n\u003cli data-end=\"5338\" data-start=\"5290\" data-section-id=\"1efz2n\"\u003eDesigned for explosive atmosphere environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"5343\" data-start=\"5340\"\u003e\n\u003ch2 data-end=\"5363\" data-start=\"5345\" data-section-id=\"v3oya7\"\u003eAlso Known As :\u003c\/h2\u003e\n\u003cp data-end=\"6787\" data-start=\"5365\"\u003eatex blower fan, explosion proof blower, hazardous area blower, anti static blower fan, industrial ventilation blower, explosion proof ventilation fan, hazardous location fan, confined space blower, industrial air blower, portable ventilation blower, industrial exhaust blower, duct blower fan, anti static ventilation system, industrial duct fan, explosion proof exhaust fan, hazardous environment ventilation equipment, industrial air mover, mine ventilation blower, refinery ventilation fan, chemical plant blower, oil and gas ventilation fan, industrial extraction blower, fresh air blower system, confined space ventilation equipment, industrial fume extraction fan, anti spark blower fan, industrial safety ventilation system, hazardous area exhaust fan, portable industrial blower, ventilation equipment industrial, industrial ducted blower, atEX certified ventilation fan, industrial air circulation blower, tunnel ventilation blower, workplace ventilation equipment, industrial cooling blower, utility ventilation fan, industrial ventilation machine, heavy duty blower fan, industrial airflow system, explosion proof air mover, industrial exhaust equipment, safety ventilation blower, industrial hazard ventilation equipment, industrial fan with duct, pvc duct blower fan, retractable duct blower, industrial ventilation solution, hazardous area air circulation system, industrial emergency ventilation equipment.\u003c\/p\u003e","brand":"Milansafety","offers":[{"title":"JIB-ATEX-200 (8\")","offer_id":52341558935826,"sku":null,"price":0.0,"currency_code":"INR","in_stock":false},{"title":"JIB-ATEX-250 (10\")","offer_id":52341558968594,"sku":null,"price":0.0,"currency_code":"INR","in_stock":false},{"title":"JIB-ATEX-300 (12\")","offer_id":52341559001362,"sku":null,"price":50000.0,"currency_code":"INR","in_stock":true},{"title":"JIB-ATEX-350 (14\")","offer_id":52341559034130,"sku":null,"price":0.0,"currency_code":"INR","in_stock":false},{"title":"JIB-ATEX-400 (16\")","offer_id":52341559066898,"sku":null,"price":0.0,"currency_code":"INR","in_stock":false},{"title":"JIB-ATEX-450 (18\")","offer_id":52341559099666,"sku":null,"price":0.0,"currency_code":"INR","in_stock":false},{"title":"JIB-ATEX-500 (20\")","offer_id":52341559132434,"sku":null,"price":0.0,"currency_code":"INR","in_stock":false},{"title":"JIB-ATEX-600 (24\")","offer_id":52341559165202,"sku":null,"price":0.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0738\/3475\/8418\/files\/Industrial-blower-01.png?v=1780570188","url":"https:\/\/milansafety.com\/products\/jarsh-atex-certified-industrial-blower-fan-with-anti-static-pvc-duct","provider":"Milansafety","version":"1.0","type":"link"}